LG’s new company headquarters building. Frener & Reifer have been contracted for the building’s central cube custom curtain walls. Buro Ehring performed ongoing building physics services, including U-Value calculations and condensation risk analysis, for the project’s custom curtain wall systems.
Responsibilities Included: Created all THERM models for the curtain wall systems. Ran U-Value calculations and condensation risk analysis for the curtain wall. Created analysis reports based on the analysis results for submittal to the design team and facade consultants. Provided consulting to F&R to improve their details where thermal bridging or condensation risk was an issue.